产品详细内容
产品型号: 61-6949-91
产品品牌: SIGMAKOKI CO., LTD.
功能
- Fabry-Perot resonators (cavities) are used to obtain the ultimate accuracy of distance and time using light.
- In order to improve the performance of this resonator, the super mirror is an ultra-high performance mirror with the reflectivity as close as possible to 1.
- Dense, defect-free, high-quality films have been deposited using ion beam sputtering (IBS).
- Using a special polishing technique, we use a low scattering substrate with a surface roughness of Ra0.1nm or less.
- We have achieved a reflective film with a reflectivity of 99.999% through our long-established film design technology.
- The scattering loss due to the substrate and film is very small, and very narrow spectral width and high finesse can be expected when the cavity is constructed.
- Available in 2 types with wavelengths of 532 nm and 1064 nm.
- * When the mirror is used alone, it does not transmit due to its high reflectivity.
- * In order to use the transmitted light, please assemble the cavity before use.
- * Handle and measure the mirror in a clean environment.
- * Trash, dust, and even trace amounts of gas in the air can greatly affect the measured value.
- * If the cavity is composed of two flat mirrors, the output from the cavity may become unstable.
- * If you are configuring a stable cavity, make sure that one or both of them are concave mirrors.
规格
- [>超镜像<>] 通用规格]
- 材料:合成石英
- 形状:平面基底
- 平行程度:<5′′′
- 基板表面精度:λ/10
- 涂层:表面,介电多层高反射涂层,背面,介电多层防反射涂层
- 发生角度:0°
- 防反射膜:R>0.15%
- 有效直径:外径的80%
- 刮-挖:10-5
- 【个别规格】
- 自适应波长:532 nm
- 外径φD:φ12.7mm
- 厚度t:6公厘
- 反射率:99.995% (即使反射率是使用CRD测量的,也可以根据测量方法和测量条件而变化。)
- 损耗:20 ppm (此值波是参考数据) 。数据不会附加到产品上。)
- 符合RoHS标准的产品