产品型号: 61-6876-37
产品品牌: SIGMAKOKI CO., LTD.

功能

  • A cube-type half-mirror that splits unpolarized light, such as a white light source or an LED light source, equally between transmitted and reflected light.
  • Accurate branching characteristics can be obtained in wide wavelength bands of white light and LED light sources.
  • Since a dielectric multilayer film is used for coating, light loss is small and light can be efficiently separated.
  • Since it is a cube type, the optical axis of the emitted light will not be translated if the beam is incident vertically.
  • Also, even if a beam of the same size as the effective diameter is injected, the transmitted or reflected light will not be lost or reduced. *Enter light from the prism side marked with ○.
  • * Reflectivity and reflectance wavelength characteristics may differ when light is inserted from the opposite prism.
  • * When using linearly polarized light such as laser light, the reflectivity and transmittance vary greatly depending on the polarization direction.
  • * When adjusting the branching ratio to 1:1, tilt the polarization azimuth to 45 degrees or use circularly polarized light.
  • * The phase difference of the incident light is not stored in transmitted light or reflected light.
  • * Use a wave plate to compensate for the phase difference.
  • * Wavelength dispersion occurs in transmitted and reflected light due to the refractive index of the material and the thickness of the glass.

规格

  • [>介电多层立方体半镜<> 通用规格]
  • 材质:BK7
  • 基材表面精度:λ/4
  • 透射光束偏振角:<5′
  • 涂层:斜率电介质多层膜,侧4面反射防止膜
  • 发生角度:0°
  • 分支比率(反射:传输):1:1
  • 入射光的偏振条件:45度方位角的非偏振光、线性偏振光或圆偏振光
  • 雷射耐久性:0.3J/cm2 (脉冲宽度10 ns,重复频率20Hz)
  • 抓取-dig:20-10
  • 有效范围:正方形外尺寸85%以内刻的圆(A=B=C≤7 mm:见方外尺寸80%的圆)
  • 【个别规格】
  • 自适应波长:390 -410 nm
  • A=B=C:10公厘
  • 透射率 (P偏振光和S偏振光的平均值) :平均值50±3%
  • 符合RoHS标准的产品

相关产品推荐

您可能还对以下产品感兴趣

62-8343-10 Millipore Express SHC墨盒过滤器30英寸。0.5/0.2μm代码7氟碳;3/pk CHGE73TF3
生命科学/分析仪器
61-0328-66 [已停用]用于合成801305 100G的十二烷二酸 8.01305.0100
生命科学/分析仪器
61-4429-11 1/4 CPP类型的Ferrule 054310-2747A
生命科学/分析仪器

61-4429-11 1/4 CPP类型的Ferrule 054310-2747A

型号: 61-4429-11 品牌: SIBATA SCIENTIFIC TECHNOLOGY LTD.
61-0292-92 醋酸铜 (II) 一水合铜 (TM) ACS 102711 250G 1.02711.0250
生命科学/分析仪器