61-6884-52 高功率偏振分束器355 nm 10 mm PBSHP-10-3550
生命科学/分析仪器

61-6884-52 高功率偏振分束器355 nm 10 mm PBSHP-10-3550

型号: 61-6884-52
品牌: SIGMAKOKI CO., LTD.

产品描述

产品型号: 61-6884-52产品品牌: SIGMAKOKI CO., LTD. 功能 Polarizati […]

联系我们

咨询热线

18866622123

微信咨询

微信号: AHY97319570

微信二维码

产品详细内容

产品型号: 61-6884-52
产品品牌: SIGMAKOKI CO., LTD.

功能

  • Polarization beam splitter designed for pulsed laser such as YAG laser.
  • Since the adhesive is not used on the surface of the prism, it is joined by optical contact, it can withstand high-power laser.
  • By transmitting P-polarized light and reflecting S-polarized light, the polarization state of the incident light can be divided into orthogonal components.
  • Since a dielectric multilayer film is used for coating, light loss is small and polarization separation can be achieved efficiently.
  • Since it is a cube type, the optical axis of the emitted light will not be translated if the beam is incident perpendicularly.
  • Also, even if a beam of the same size as the effective diameter is injected, the transmitted or reflected light will not be lost or reduced.
  • A Grantomson Prism (GTPC) with a high extinction ratio is also available.
  • * The characteristics of transmittance and extinction ratio may change if light enters from the prism side which is not marked with ○.
  • * Before use, make sure that the energy density of the incident laser beam does not exceed the laser capacity.
  • * If the laser beam is narrowly narrowed by a lens or concave reflection, the energy density may exceed the laser capacity of the device and the device may be damaged.
  • * The extinction ratio of reflected light is slightly lower than that of transmitted light. (Approx. 3/100)
  • * Transmittance and extinction ratio will be poor when using at wavelengths other than the applicable wavelength.
  • * Wavelength dispersion occurs in transmitted and reflected light due to the refractive index of the material and the thickness of the glass. In addition, chromatic aberration and spherical aberration may occur when a converging or diverging beam is injected.

规格

  • [>高功率偏振分束器< 通用规格]
  • 材料:BK7合成石英
  • 基材表面精度:λ/4
  • 透射光束偏振角:<10′
  • 涂层:斜率电介质多层膜,侧4面反射防止膜
  • 发生角度:0°
  • P偏振光透过率:>97%
  • 传输消光比:Ts:Tp=1:200
  • 抓取-dig:20-10
  • 有效范围:正方形外尺寸85%的内切圆
  • 【个别规格】
  • 自适应波长:355 nm
  • A=B=C:10公厘
  • 材料:合成石英
  • S偏振光反射比:>97%
  • 雷射耐久性*:2J/cm2
  • *雷射脉冲宽度10 ns,重复频率20Hz
  • 符合RoHS标准的产品

相关产品推荐

您可能还对以下产品感兴趣

61-0324-43 [已停用]用于合成800107 1L的乙酰乙酸甲酯 8.00107.1000
生命科学/分析仪器
62-8377-31 组蛋白乙酰转移酶p300抑制剂II,L002 5.05298.0001
生命科学/分析仪器
2-7424-01 无菌4盎司容器120mL 13-711-65
生命科学/分析仪器

2-7424-01 无菌4盎司容器120mL 13-711-65

型号: 2-7424-01 品牌: Thermo Fisher Scientific K.K.
61-0346-16 [已停用]4-异丙氧基苯甲酸合成814461 10G 8.14461.0010
生命科学/分析仪器